TABLE OF CONTENTS ABOUT THIS MANUAL BEFORE GETTING STARTED This booklet is an integral and essential part of the product. Each unit is tested under operating conditions and is thoroughly Please carefully read the guidelines and warnings contained inspected before shipment. At the time of shipment, the herein as they are intended to provide the user with essential carrier accepts responsibility for the unit.
IMPORTANT SAFETY INSTRUCTIONS ! Intended Use F Power • The dispenser is for indoor use only • Follow all local electrical codes when making connections. • This appliance is intended to be used in commercial applications such as restaurants or similar. •...
! Automatic Agitation • Units are equipped with an automatic agitation system and will activate unexpectedly. • CAUTION: Do not place hands or foreign objects in the ice bin tank. Unplug the dispenser during servicing, cleaning, and sanitizing. • CAUTION: To avoid personal injury, do not attempt to lift the dispenser without assistance.
Blue Star IBD CB Series 25” & Renew IBD CB Series 25” 40.25 in. A. Top Cover 25.0 in. 30.5 in. B. Merchandiser C. Valves D. Splash Plate E. Drip Tray DIMENSIONS CARBONATED WATER SUPPLY Width: 25.0 inches (635 mm) Min Flowing Pressure: 25 PSI (0.172 MPA) Depth: 30.5 inches (775 mm) Max Static Pressure: 65 PSI (0.448 MPA)
Blue Star IBD CB Series 30” & Renew IBD CB Series 30” 40.25 in. 30.0 in. 30.5 in. A. Top Cover B. Merchandiser C. Valves D. Splash Plate E. Drip Tray CARBONATED WATER SUPPLY DIMENSIONS Min Flowing Pressure: 25 PSI (0.172 MPA) Width: 30 inches (762 mm) Max Static Pressure: 65 PSI (0.448 MPA) Depth: 30.5 inches (775 mm)
Features of the Blue Star IBD CB Series 22”/25”/30” Cold Carbonation Capability • Water is pre-chilled in the cold plate before entering the carbonator tank. • This allows it to absorb CO more effectively inside the tank. Three-Way Adjustable Back Blocks •...
Read This Manual This manual was developed by Lancer Corporation as a reference guide for the owner/operator and installer of this dispenser. Please read this manual before installation and operation of this dispenser. See pages 20 - 23 for troubleshooting or service assistance.
NOTE level lines. Repeat this procedure for the remaining three sides. Level unit if necessary. For optimum Lancer does NOT recommend the use of shaved or performance place the unit at a 0° tilt. The maximum flake ice in the dispenser. tilt is 5°.
Merchandiser. An adapter plate is required when installing an icemaker. Ensure manual fill is accessible. Contact your Sales Representative or Lancer Customer Clean and maintain icemaker per manufacturer’s Service for more information. instructions. Attach Bin Stat Bracket As Shown...
Drain Tube to become clogged with coffee or tea grounds, or other solid particles. Remote Pump Installation If necessary, install water booster (Lancer PN MC-163172) Complete the carbonated water line connection, installed in between water supply and the unit. the previous section, between the remote pump deck and carbonated water inlet on the unit.
Installing Remote Syrup Pumps - Bag In Box Install BIB rack and remote pumps according to Install BIB (bag in box) connectors onto the syrup pump manufacturers’ instructions. inlet tubing. ! ATTENTION Once pumps and BIB rack are installed, measure and cut tubing to length between the pump CO inlets, then connect Use proper connector for syrup manufacturer...
Installing CO Supply Connect high pressure CO regulator assembly to CO Connect tubing routed from the CO inlet at the unit to one cylinder or bulk system. of the low pressure CO regulator manifold outlets. ! ATTENTION Connect tubing routed from the tee at the syrup pumps to the second outlet of the low pressure CO regulator Before installing regulator, assure that a seal (washer...
Dispenser Setup Turn on water source. Turn on CO at the source then, using a screwdriver, adjust the high pressure regulator at the source to 110 PSI (0.758 Open the pressure relief valve located on the front of the MPA) then tighten locknut with wrench. unit, by flipping up on the valve cap lever.
5 for reference). Re-open syrup shut-off at mounting block. Using a Lancer ratio cup verify water flow rate (5 oz. in 4 Activate valve to purge syrup until steady flow is achieved. sec.). Use a screwdriver to adjust if needed.
General Information • Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
Ice Bin Cleaning - Start-Up and Monthly NOTE Repeat Step 6 for all exterior surfaces of the dispenser. Using hot water, thoroughly rinse away the cleaning Refer to the Automatic Agitation Warning on page 4. solution. 10. Wearing sanitary gloves, soak and clean cloth towel in Disconnect power to the dispenser Sanitizing Solution and wash all surfaces of removable Remove Top Cover.
Cleaning and Sanitizing Nozzles Disconnect power, so as to not activate valve while Rinse nozzle and diffuser with warm water. cleaning. Wash nozzle and diffuser with cleaning solution then Remove nozzle by twisting counter clockwise and pulling immerse in sanitizing solution and let sit for fifteen (15) down.
Ice Chute Cleaning NOTE NOTE It is recommended to perform this procedure monthly, Always remove the ice chute lever before removing or more often if desired. Use the cleaning solution the splash plate. described above. An alternate solution of one part water to one part vinegar may be used to remove Remove the Ice Chute Assembly base by removing the four water spots and calcium deposits.
Page 20
TROUBLE CAUSE REMEDY Syrup only dispensed. No Improper water flow to dispenser. Check for water flow to dispenser. water, but CO gas dispensed Carbonator pump motor has timed out. Reset by turning the unit OFF, then ON with syrup. by using the circuit breaker on the power Liquid level probe not connected properly supply or momentarily unplugging unit.
TROUBLE CAUSE REMEDY Insufficient syrup flow. Insufficient CO pressure to BIB pumps. Adjust CO pressure to BIB pumps to 80 PSI (0.552 MPA) (min. 70 PSI (0.483 Shutoff on mounting block not fully open. MPA). Do not exceed manufacturer’s Foreign debris in syrup flow control. recommendations.
Remote Syrup/Flavor Shot Pump Troubleshooting TROUBLE CAUSE REMEDY BIB pump does not operate Out of CO , CO not turned on, or low CO Replace CO supply, turn on CO when dispensing valve is pressure. supply, or adjust CO pressure to 70-80 opened.
Wiring Diagram - 115 Volt Dispenser Disposal To prevent possible harm to the environment from improper disposal, recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased. Comply with local regulations regarding disposal of the refrigerant and insulation.