TROUBLE
4.8 Water only dispensed; no syrup; or
syrup only dispensed, no water
4.9 No water just syrup, (Ice bank grew to
water inlet line to carbonator tank.)
4.10 Valve will not shut off.
CAUSE
A. Water or syrup shutoff on mounting
block not fully open.
B. Improper or inadequate water or syrup
flow.
C. BIB supply too far from
dispenser.
D. CO2 pressure too low.
E. Stalled or inoperative BIB
pump
F. Kinked line.
A. Low water bath level.
B. Unit not level.
C. Syrup in water bath.
D. Water cage is out of position.
E. Refrigerant leak.
F. Check water supply.
G. Carbonator timed out.
H. PCB malfunctioning.
A. Cup lever may be sticking or binding.
B. Switch not actuating freely.
C. Solenoid armature not returning to
bottom position.
18
REMEDY
A. Open shutoff fully.
B. Remove valve from mounting block,
open shutoffs slightly and check water
and syrup flow. If no flow, check
dispenser for freeze-up or other
problems. Ensure BIB connection is
engaged.
C. Check that BIB supply is within six (6)
feet of the dispenser.
D. Check the CO2 pressure to the pump
manifold to ensure it is between 70
and 80 PSI.
E. Check CO2 pressure and/or replace
pump.
F. Remove kink or replace line.
A. Add water until it flows from overflow
tube.
B. Level unit and add water.
C. Melt ice bank. Remove all water. Refill.
Locate possible syrup leak area and
repair.
D. Reposition water cage.
E. Find leak and recharge unit. (If unit is
not frozen.)
F. Turn water ON and shut unit OFF,
G. Turn unit OFF then ON to reset
H. Refer to Section 6.
A. Correct or replace lever.
B. Check switch for free actuation.
C. Replace defective armature or spring.