Virtual Quality Management (Vqm) System Display Trouble Shooting Messages - ELECTRO FREEZE SLX400C Operator's Manual

Genesis series, soft serve freezer
Table of Contents

Advertisement

14.1
Virtual Quality Management (VQM) System
What the
Action taken
display
in unit when
will read
error is
present
System
Comm.
completely shuts
Error UI
down
System
No Comm
completely
shuts down
Barrel
Refrigeration
is off, Hopper
Low PSI
Refrigeration
continues to
operate
Barrel
Refrigeration
is off, Hopper
High PSI
Refrigeration
continues to
operate
Barrel
Refrigeration
in Night
Barrel Rfg.
Mode, Hopper
refrigeration
stays on
Barrel
Refrigeration
switches to night
Hopper Rfg
mode. Hopper
system cycles 5
min. on 45 min.
off
Affected Barrel
Barrel Temp
in night temp.
cycle mode
Affected barrel in
night temp. mode,
Hopper Temp
hopper in time cycle
mode
184582-01
ELECTRO FREEZE Soft Serve Models SLX400C
Display Trouble Shooting Messages
Detailed
Method to
description
reset error
The Main P.C.
Board is not
Cycle the Main
communicating
Power Switch
with the U.I. Board
The U.I. Board is
not communicating
Cycle the Main
with the Main P.C.
Power Switch
Board
Low Pressure
(PSI), this will
Cycle the Main
occur when the
Power Switch
LPCO is tripped/
opens.
High Pressure
(PSI), this will
Cycle the Main
occur when the
Power Switch
HPCO is tripped/
opens.
Barrel
Refrigeration
Error. This occurs
Cycle the Main
when the system
Power Switch
run time exceeds
90 minutes
Hopper
Refrigeration Error.
Occurs when
Cycle the Main
hopper system run
Power Switch
time exceeds 90
minutes
Barrel Temperature
Out. Occurs when
barrel thermistor
Cycle the Main
is above or below
Power Switch
temp. limit for 1
minute without
change
Hopper Temperature
Out. Occurs when
hopper thermistor is
Cycle the Main Power
above or below temp.
Switch
limit for 1 minute
without change
Probable cause of Error
Code
1. Faulty Wire Connection
2. Programming Issue
3. Defective Board
1. Faulty Wire Connection
2.Programming Issue
3. Defective Board
1. Low Pressure Control is
Faulty
2. Refrigerant Flow valve is
sticking closed
3. Shortage of refrigerant
1. Dirty Condenser coil or
condenser pre-filter
2. Failed Condenser fan
motor (Air Cooled Only)
3. Water Supply Shut off
(Water Cooled Only)
1. Dirty Condenser
2.Shortage of refrigerant
3. Moisture in system.
4. Compressor Failing
5. Faulty Thermistor
1. Dirty Condenser
2. Shortage of refrigerant
3. Moisture in system.
4. Compressor Failing
5. Faulty Thermistor
1. Faulty Thermistor
2. Refrigeration System
malfunction
1. Faulty Thermistor
2. Refrigeration System
malfunction
Remedy
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro
Freeze Distributor for
Service.
1. Remove and clean
Condenser pre-filter.
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro
Freeze Distributor for
Service.
Contact your Electro Freeze
Distributor for Service.