Trouble Shooting Tables
PROBLEM
PROBABLY CAUSE
1. Freezer unplugged.
2. Fuse or breaker blown at main disconnect.
Unit does not
operate.
3. Off on high pressure cut-out control.
4. Off on low pressure cut-out control.
5.
Leakage of mix
1.
or water from
drain tube to drip
2.
tray.
3. Beater shaft end play not set properly.
Compressor
1. Faulty contactor.
does not operate
or operates
improperly.
2. Disconnected or broken wire in switch.
40
Disconnected or broken wire in electrical
circuit.
Damaged beater shaft seal or installed
improperly.
Beater shaft pitted or damaged where
o-ring rides.
(continued)
REMEDY
1. Plug in freezer.
Make sure your freezer is connected
to a separate circuit independent from
any other electrical equipment. Have
2.
technician check fuse or breaker size
and check voltage; if not within 10% of
nameplate rating call power company.
Refer to Troubleshooting Table –
3.
Discharge pressure too high.
Contact your Electro Freeze distributor
4.
for service.
Contact your Electro Freeze distributor
5.
for service.
Replace cup seals on washer. Install
1.
properly.
2. Replace beater shaft.
Contact your Electro Freeze distributor
3.
for service.
Contact your Electro Freeze Distributor
1.
for service.
Contact your Electro Freeze Distributor
2.
for service.
184582-01