ELECTRO FREEZE SLX400C Operator's Manual page 56

Genesis series, soft serve freezer
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Models SLX400C
14.1
Virtual Quality Management (VQM) System
Display Trouble Shooting Messages (continued)
What the
Action taken
display
in unit when
will read
error is
present
Last Cones /
Number of Cones
Mix Low
before Mix Out
Alternates in
Condition
screen
Affected Barrel
MIX OUT
Beeps to alert user
of Mix Out Condition
System completely
Head Sw
shuts down
Affected barrel in off
Motor OVLD
mode , hopper still
operates
System remains
Clock Error
operational
Control Displays
Power Fail
Power Fail
if main line
power has been
disrupted
46
Detailed
Method to
description
reset error
Mix Low. Occurs when
Refill with mix to satis-
low mix probe signal is
fy probe and unit auto
detected for 30 sec.
resets
Mix Out. Occurs
when last cone value
Auto reset after mix
reached while in mix
probe is satisfied
low condition
Head Switch Open. Oc-
curs when head switch
is open with power
Auto reset after head
applied to unit ( When
switch is closed
freeze, night, or clean
mode are selected
Motor Overload Open.
Occurs when motor
Cycle the Main Power
current is 0 when motor
Switch
is given an on signal
Clock Error occurs
when the signal is lost
All timer functions use
from the Real time
default data/time
clock
Once the Main
When the unit
power is restored
experiences
the unit will
a power fail in
display the error
Freeze or Night
until the SELECT
mode, unit will
button is pressed
restore in Night
to acknowledge
Mode.
the error
Probable cause of Error
Code
Hopper running low on Mix
1. Hopper out of Mix
2. Mix level Control not Function-
ing properly
1. Head Assembly not installed
2. Magnetic head Switch defective
3. Loose Wire Connection
4. Programming issue
1. Product too cold
2. Loose wire Connection
3. Open starter coil
4. Faulty Capacitor (1 ph. Only)
5. Faulty Beater Motor
1. Main Incoming power to
unit was disrupted
Remedy
Re-fill unit with Mix
1. Re-fill unit with Mix
2. Contact your Electro Freeze
Distributor for Service.
1. Install Head Assembly
2. Contact your Electro Freeze
Distributor for Service.
1. Adjust product temperature
2. Contact your Electro Freeze
Distributor for Service.
Contact your Electro Freeze
Distributor for Service.
1. Check to ensure power
cord is properly plugged
into socket.
2. Check to see if main
power to the building was
cycled.
3. Check condition of Main
power cord.
4. Check to see if the main
circuit breaker has tripped.
5. Contact your Electro
Freeze Distributor for
Service.
184582-01