Comtech EF Data LBC-4000 Installation And Operation Manual page 88

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and
Qualifier)
Retrieve Module
N/A
Equipment Type
Retrieve
N/A
Maintenance Status
Retrieve
N/A
Utility Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes between
Response to Query
12 bytes,
Query only.
alphanumeric
The unit returns a string indicating the frequency of the selected
module and the module type (Up-Link or Down-Link) in the form
RET_x_ where:
x = 'A' or 'B'
Example: RET_A_140_DL or RET_B_070_UL
203 bytes,
Query only.
alphanumeric
Used to Query the maintenance status of the unit in the form
RMS_'cr' :
12VT1=xxx.x'cr'
08VT1=xxx.x'cr'
05VT1=xxx.x'cr'
12VT2=xxx.x'cr'
08VT2=xxx.x'cr'
05VT2=xxx.x'cr'
VTREF=xxx.x'cr'
IFLOA=xxx.x'cr'
RFLOA=xxx.x'cr'
PIN_A=xxx.x'cr'.
POUTA=xxx.x'cr'
TEMPA=xxx.x'cr'
IFLOB=xxx.x'cr'
RFLOB=xxx.x'cr'
PIN_B=xxx.x'cr'
POUTB=xxx.x'cr'
TEMPB=xxx.x'cr''
98 bytes
Query only.
alphanumeric
Used to Query the utility features of the unit in the form RUS_
where:
TIME=hh:mm:ss
DATE=mm/dd/yy
FSDA=xxxx (Reserved for future use)
FSDB=xxxx (Reserved for future use)
BVFD=yyy
SCRT=zzz
BULK=FW9965X (where X is the revision letter)
M&C =FW9966X (where X is the revision letter)
FPGA=FW9967X (where X is the revision letter)
Description of Arguments
48 and 57)
12 VDC Supply #1 in volts.
8 VDC Supply #1 in volts.
5 VDC Supply #1 in volts.
12 VDC Supply #2 in volts.
8 VDC Supply #2 in volts.
5 VDC Supply #2 in volts.
Ref Osc tuning voltage in volts.
Conv A IFLO tuning voltage, V.
Conv A RFLO tuning voltage, V.
Conv A Input power in dBm.
Conv A Output power in dBm.
Conv A temperature in deg C.
Conv B IFLO turning voltage, V.
Conv B RFLO tuning voltage, V.
Conv B Input power in dBm.
Conv B Output power in dBm.
Conv B temperature in deg C
6–16
Query
Response to Command
(Instruction Code
(Target to controller)
and qualifier)
N/A
RET_x_
N/A
RMS_
N/A
RUS_
Revision 4
MN/LBC4000.IOM
Response to query
(Target to controller)
RET_x....x
(see Description of
Arguments for details)
RMS_
x....x
(see Description of
Arguments for details)
RUS_
x....x
(see Description of
Arguments for details)

Advertisement

Table of Contents
loading

Table of Contents