Lbc-4000 L-Band Upconverter Idu - Comtech EF Data LBC-4000 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Introduction
1.4.6

LBC-4000 L-Band Upconverter IDU

Input Frequency
Output Frequency
Input/Output Impedance
Input Return Loss
Output Return Loss
Input connector
Output connector
Gain
Ripple
Slope
User Attenuation Range
Input Power Level
Output Power, P1dB
Third Order Intercept
Carrier Spurious
Non-Carrier Spurious
Transmit Phase Noise
Over Time
Stability
Over Temp
 
 
70 MHz ±18 MHz (140 MHz ±36 MHz optional)
950 MHz to 2000 MHz, 1 kHz steps
50Ω
18 dB minimum
15 dB minimum
Type 'BNC' female
Type 'N' female
25 dB ±1 dB nominal at minimum attenuation
• ±.5 dB over any ±18 MHz for 70 MHz IF units
• ±.5 dB over any ±36 MHz for 140 MHz IF units
0.05 dB/MHz
0 to 40 dB, in 0.25 dB steps (0.1 dB optional)
To ±10 dBm maximum
+10 dBm minimum
+20 dBm minimum
-60 dBc
-75 dBm
Exceeds MIL-STD-188-164A
±1 X 10
/Day
-9
±1 x 10
32º to 122ºF (0º to 50ºC)
-8
 
1–7
Revision 4
MN/LBC4000.IOM

Advertisement