Comtech EF Data LBC-4000 Installation And Operation Manual page 85

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and
Qualifier)
Retrieve Firmware
N/A
Number
Firmware Image
IMG_
Selection
List all alarms
N/A
Mute State
MUT_
Online Unit
N/A
Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes between
Response to Query
Query only.
Gets the Firmware Numbers of the unit.
Example: FRW_
BULK=FW/9965X
M&C =FW/9966X
FPGA=FW/9967X
(Where 'X' denotes the firmware revision letter)
1 byte
Command or query:
Selects which bulk image to boot from where x =
1=bulk image 1
2=bulk image 2
variable
Query only.
This command retrieves a list of the stored alarms.
List All Alarms:
Confirmation:
xx yyyyyyyyyyy
xx yyyyyyyyyyy
xx yyyyyyyyyyy
"
"
"
"
xx yyyyyyyyyyy
Where:
xx = stored fault number.
Yyyyyyyyyyy = fault description.
Hh:mm:ss = fault time.
Mm/dd/yy = fault date.
5 bytes,
Command or Query.
alpha
Mutes/Unmutes the converter in the form MUT_x_yyy
where:
x = 'A' (Converter A) or 'B' (Converter B)
yyy = ON (mute) or OFF (unmute)
Example: MUT_A_OFF (Unmutes Converter A)
1 byte
Query only.
alphanumeric
Indicates which slot is online in the form ONL_x where:
x = A or B (depending on which Converter is online).
Description of Arguments
48 and 57)
LAA_'cr'
LAA_'cr'
hh:mm:ss mm/dd/yy'cr'
hh:mm:ss mm/dd/yy'cr'
hh:mm:ss mm/dd/yy'cr'
"
"
"
"
hh:mm:ss mm/dd/yy'cr''lf']
6–13
Query
Response to Command
(Instruction Code
(Target to controller)
and qualifier)
N/A
FRW_
Same as command
IMG_
N/A
LAA_
Same as command
MUT_x_
N/A
ONL_
Revision 4
MN/LBC4000.IOM
Response to query
(Target to controller)
FRW_
(see Description of
Arguments for details)
IMG_x
LLA_
xx y..y h..s m..y
(see Description of
Arguments for details)
MUT_x_yyy
(see Description of
Arguments for details)
ONL_
(see Description of
Arguments for details)