Comtech EF Data LBC-4000 Installation And Operation Manual page 82

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and
Qualifier)
Concise
N/A
Alarm Status
Concise
N/A
Configuration Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes between
Response to Query
13 bytes numeric
Query only.
Used to Query the Alarm Status of the unit, in the form
CAS_abcdefghijklm'cr''lf', where:
a = 1 if 12VDC #1 Fault, else 0.
b = 1 if 8VDC #1 Fault, else 0.
c = 1 if 5VDC #1 Fault, else 0.
d = 1 if 12VDC #2 Fault, else 0.
e = 1 if 8VDC #2 Fault, else 0.
f = 1 if 5VDC #2 Fault, else 0.
g = 1 if REF LD Fault, else 0.
h = 1 if IFLO A Fault, else 0.
i = 1 if RFLO A Fault, else 0.
j = 1 if TEMP A Fault, else 0.
k = 1 if IFLO B Fault, else 0.
l = 1 if RFLO B Fault, else 0.
m = 1 if TEMP B Fault, else 0.
52 bytes
Query only.
numeric
Used to query the summarized version of RCS, in the form
CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnnopqqqqrs
where:
aaaaa.aaa = Conv A frequency in MHz
bb.bb = Conv A attenuation in dB
c = Conv A mute state, 0 = 6–10nmated, 1 = muted
d.d = Conv A slope adjust
e = Conv A online/offline (redundancy)
fffff.fff = Conv B frequency in MHz
gg.gg = Conv B attenuation in dB
h = Conv B mute state, 0 = unmuted, 1 = muted
i.i = Conv B slope adjust
j = Conv B online/offline (redundancy)
k = Converter redundancy
l = auto fault recovery, 1=auto, 0=manual
m = external ref present, 0=no ext ref, 1=present
nnn = internal ref. Oscillator adjust (000-255)
o = remote mode, 1=remote, 0=local
p = remote interface, 0=EIA-232, 1=EIA-485
qqqq = remote address (0-9999)
r = remote baud rate (0=38400, 1=19200, 2=9600,
3=4800, 4=2400, 5=1200)
s = remote data format (0 = 8N1, 1=7E2, 2=7O2)
Description of Arguments
48 and 57)
6–10
Query
Response to Command
(Instruction Code
(Target to controller)
and qualifier)
N/A
CAS_
N/A
CCS_
Revision 4
MN/LBC4000.IOM
Response to query
(Target to controller)
CAS_x....x
(see Description of
Arguments for details)
CCS_
x....x
(see Description of
Arguments for details)