Comtech EF Data LBC-4000 Installation And Operation Manual page 83

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and
Qualifier)
Configure Mute Mode
CMM_
Concise
N/A
Maintenance Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes between
Response to Query
5 bytes,
Command or Query.
alpha
Turns the mute mode ON or OFF.
When mute mode is OFF (default), the unit will mute upon
changing RF frequency. When mute mode is ON, the unit will
remain whatever its mute state upon changing RF frequency: In
the form CMM_y_xxx'cr''lf'] where:
y = 'A' (Converter A) or 'B' (Converter B)
xxx = ON (mute) or OFF (unmute)
Example: CMM_A_OFF (Unmutes Converter A)
85 bytes numeric
Query only.
Used to Query the Maintenance Status of the unit in concise
format, in the form
CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll.lm
mm.mnnn.nooo.oppp.pqqq.q'cr''lf' where:
aaa.a = 12 VDC supply #1 in volts
bbb.b = 8 VDC supply #1 in volts
ccc.c = 5 VDC supply #1 in volts
ddd.d = 12 VDC supply #2 in volts
eee.e = 8 VDC supply #2 in volts
fff.f= 5 VDC supply #2 in volts
ggg.g = Ref Osc tuning voltage in volts
hhh.h = Converter A IFLO tuning voltage in volts
iii.i= Converter A RFLO tuning voltage in volts
jjj.j = Converter A Input Power in dBm (Reserved
for future use)
kkk.k = Converter A Output Power in dBm (Reserved for
future use)
lll.l= Converter A temperature in degrees C
mmm.m = Converter B IFLO tuning voltage in volts
nnn.n= Converter B RFLO tuning voltage in volts
ooo.o = Converter B Input Power in dBm (Reserved for
future use)
ppp.p = Converter B Output Power in dBm (Reserved for
future use)
qqq.q = Converter B temperature in degrees C
Description of Arguments
48 and 57)
6–11
Query
Response to Command
(Instruction Code
(Target to controller)
and qualifier)
Same as command
CMM_y_
N/A
CMS_
Revision 4
MN/LBC4000.IOM
Response to query
(Target to controller)
CMM_y_xxx
(see Description of
Arguments for details)
CMS_
x....x
(see Description of
Arguments for details)

Advertisement