LBC-4000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and
Qualifier)
Retrieve
N/A
Alarm Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes between
Response to Query
122 bytes
Query only.
alphanumeric
Used to Query the Alarm status of the unit, where: xx = OK (no
fault) or FT (fault):
12VDC1_xx'cr'
08VDC1_xx'cr'
05VDC1_xx'cr'
12VDC2_xx'cr'
08VDC2_xx'cr'
05VDC2_xx'cr'
REFLD_xx'cr'
IFLOA_xx'cr'
RFLOA_xx'cr'
TEMPA_xx'cr'
IFLOB_xx'cr'
RFLOB_xx'cr'
TEMPB_xx'cr''lf'
*Note: REFLD is only returned if an external reference is
present.
Description of Arguments
48 and 57)
12 VDC #1 Fault.
8 VDC #1 Fault.
5 VDC #1 Fault.
12 VDC #2 Fault.
8 VDC #2 Fault.
5 VDC #2 Fault.
Ref Osc. Lock Detect Fault.*
Conv A IFLO Lock Detect Fault.
Conv A RFLO Lock Detect Fault.
Conv A Over Temperature Fault.
Conv B IFLO Lock Detect Fault.
Conv B RFLO Lock Detect Fault.
Conv B Over Temperature Fault.
6–14
Query
Response to Command
(Instruction Code
(Target to controller)
and qualifier)
N/A
RAS_
Revision 4
MN/LBC4000.IOM
Response to query
(Target to controller)
RAS_
x....x
(see Description of
Arguments for details)