Select: Util (Utility); Vacuum Fluorescent Display (Vfd) ....................................................................................... 5–4 - Comtech EF Data LBC-4000 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Front Panel Operation
FAULTS
Stored
Clear all stored
 
Upon  selecting  Clear,  you  are  prompted  to  choose  NO  or  YES.  Use  the  [↑][↓]  arrow  keys  to 
select your choice, and then press [ENT].  
 
By  selecting  YES,  the  event  log  is  cleared  and  you  are  then  returned  to  the  previous  menu.  
However, if there are faults present on the unit at this time, they will be re‐time‐stamped, and 
new log entries will be generated. 
5.2.4

SELECT: Util (Utility)

UTIL: Clock LEDtst Relay
VFD ScrSaver FWInfo ApID
 
Use the [←][→] arrow keys to select Clock, LEDtst, Relay, VFD, ScrSaver, FWInfo, or ApID and 
then press [ENT].  
 
The following table identifies each submenu available from the SELECT: UTIL menu branch – 
typical for Converter Unit A or Unit B – its content section in this chapter, and functional 
description of each submenu: 
 
Submenu
Clock
LEDtst
Relay
VFD
ScrSaver
FWInfo
ApID
 
Clear
Faults? NO
Sect
Functional Description
5.2.4.1
Edits the date and Real-Time Clock time settings
Runs a diagnostic test on each of the two sets of five front panel Light-Emitting
5.2.4.2
Diodes (LEDs
5.2.4.3
Selects Fault Relay Logic
5.2.4.4
Adjusts the brightness level of the Vacuum Fluorescent Display (VFD)
5.2.4.5
Screen saver
5.2.4.6
Displays and selects the installed internal firmware images
5.2.4.7
Use to enter an 48-character Application ID string (2 lines, 24 characters/line)
5–12
Revision 4
MN/LBC4000.IOM

Advertisement

Table of Contents
loading