14. INTEGRATOR & PSU  
 
TOUCHSAFE PRO PANEL SETUP
 
Go to the Touchsafe Pro Master Panel (ID 1), Logon as an Engineer and select the Panel Details option...  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Go to the Touchsafe Pro Panel with the Integrator connected, Logon as an Engineer and select the Paging 
Setup option... 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
BEEP CODES
 
ESPA Beep Code 
Pager Beep Pattern 
 
8 single beeps 
8 double beeps 
8 triple beeps 
8 four beeps 
 
Enter the Beep Code to choose the beep pattern to sound for each call type. 
 
 
 
 
 
Select the Panel ID the Integrator is being 
connected to from the Paging Panel  
pull‐down box.  
Note: this only needs to be set on the  
Master Panel (ID 1). 
 
Press the Save button then Close to exit. 
 
Set the Protocol option to ESPA/MaxPage.
 
Select the Beep Codes you want the Pager 
to sound from the pull‐down boxes 
alongside each call type.  
Note: only 4 different beep patterns are 
available with the ESPA option ‐ see the 
Beep Codes table below. 
 
Set the Re‐paging Delay from the  
pull‐down box, if a pager call is not 
accepted when this period expires the call 
will be resent. 
 
Press the Save button then Close to exit. 
Doc No. FM5640 issue 3 Page 20   