14. INTEGRATOR & PSU
TOUCHSAFE PRO PANEL SETUP
Go to the Touchsafe Pro Master Panel (ID 1), Logon as an Engineer and select the Panel Details option...
Go to the Touchsafe Pro Panel with the Integrator connected, Logon as an Engineer and select the Paging
Setup option...
BEEP CODES
ESPA Beep Code
Pager Beep Pattern
1
8 single beeps
2
8 double beeps
3
8 triple beeps
4
8 four beeps
Enter the Beep Code to choose the beep pattern to sound for each call type.
Select the Panel ID the Integrator is being
connected to from the Paging Panel
pull‐down box.
Note: this only needs to be set on the
Master Panel (ID 1).
Press the Save button then Close to exit.
Set the Protocol option to ESPA/MaxPage.
Select the Beep Codes you want the Pager
to sound from the pull‐down boxes
alongside each call type.
Note: only 4 different beep patterns are
available with the ESPA option ‐ see the
Beep Codes table below.
Set the Re‐paging Delay from the
pull‐down box, if a pager call is not
accepted when this period expires the call
will be resent.
Press the Save button then Close to exit.
Doc No. FM5640 issue 3 Page 20