Performance Verification
Network Port Test
Serial Port Test
1–10
Checks the Ethernet network port. Requires a network connection with a DHCP
server.
1. Connect the NetTek Analyzer Platform RJ45 Ethernet port to a DHCP-enabled
network server.
2. Select Network Port Test; then select Run.
A Test failed is recorded in the Failure Log if the NetTek Analyzer cannot obtain
an I.P. address from the DHCP-enabled network server.
Check the serial port signal lines by setting the output control lines and reading
the corresponding status lines. Writes, reads, and validates a data pattern at
varying baud rates.
NOTE.
This test requires a custom DB-9F serial loop-back connector.

Table 1-1: DB- 9F serial loop-back connector pin-out

Connect pin
1 (DCD)
6 (DSR)
2 (RX)
5 (SGND)
8 (CTS)
9 (RI)
1. Install the custom DB-9 loop-back connector on the RS-232 serial port. Refer
to the user manual for port location.
2. Select Serial Port Test; then select Run.
A Test failed is recorded in the Failure Log if the loop-back connector is not
installed when prompted.
To pin
4 (DTR)
4 (DTR)
3 (TX)
NC
7 (RTS)
7 (RTS)