BB1000-NA, BB1000-EU & BB1000-UK Breakout Box for Tektronix Power Analyzers Instruction Manual Register now! Click the following link to protect your product. ► www.tektronix.com/register www.tektronix.com *P071323900* 071-3239-00...
Page 3
Warranty Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
Do not connect or disconnect probes or test leads while they are connected to a voltage source. Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by Tektronix to be suitable for the product.
Page 8
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress injuries. Use only the Tektronix rackmount hardware specified for this product. Probes and test leads Before connecting probes or test leads, connect the power cord from the power connector to a properly grounded power outlet.
Important safety information Beware of high voltages. Understand the voltage ratings for the probe you are using and do not exceed those ratings. Connect and disconnect properly. De-energize the circuit under test before connecting or disconnecting the current probe. Connect the probe reference lead to earth ground only. Do not connect a current probe to any wire that carries voltages above the current probe voltage rating.
Important safety information Terms in this manual These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols and terms on the product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking.
EN 61010-2-030. Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 2-030: Particular requirements for testing and measuring circuits. U.S. nationally recognized testing laboratory listing (BB1000-NA only) UL 61010-1. Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General Requirements.
Page 12
Compliance information Safety class Class 1 – grounded product. Pollution degree descriptions A measure of the contaminants that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external. Products should be used only in the environment for which they are rated.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Preface Preface This document describes how to connect and use the following models of the BB1000 breakout box: Model BB1000-NA: 120 V North America Model BB1000-EU: 240 V Europe Model BB1000-UK: 240 V United Kingdom Instruction Manual...
BB1000-xx breakout box The simplest and safest way to make a connection to your device under test is to use the Tektronix BB1000-xx breakout box. The breakout box provides a line output socket to power the device under test, and 4 x 4 mm sockets for direct connection to the Tektronix power analyzer terminals.
Connection sequence 1. Using the test leads provided with the Tektronix power analyzer, make the voltage and current connections between the breakout box and the input jacks on the power analyzer. Typical connections are shown for the PA1000 and PA4000 power analyzers on the following pages.
BB1000-xx breakout box Measuring currents of 500 mA or more Under most test conditions, the requirement is to measure the voltage across the device under test. The figure below shows how to make these connections. Figure 3: Typical connection for currents above 500 mA Instruction Manual...
BB1000-xx breakout box Measuring currents of 500 mA or less For standby power measurements, the current and power in the voltmeter circuit can be significant when compared to current being measured. For standby measurements the voltage is connected on the supply side of the current shunt. The figure below shows how to make the connections to the breakout box and analyzer for low current measurements.
BB1000-xx breakout box Specifications Table 1: Electrical specifications Characteristic BB1000-NA BB1000-EU BB1000-UK Operating voltage (line 120 VAC 240 VAC 240 VAC input/output) Maximum line current draw (device 10 A 10 A 10 A under test) Maximum voltage between VHI 125 VAC...
Page 20
Largest Supplier of Electrical and Electronic Components Click to view similar products for manufacturer: tektronix Other Similar products are found below : TDS3BATC DCM320 TDS3TRG AFG1022 AFG3102C TBS1102B TCP2020 TCP312A TDS2022C MDO3EMBD MDO3AFG MDO3COMP DMM4020 DPO2CONN TPP1000 P2221 TPA-BNC P6021A P5122 TBS1202B TBS1072B A621 PWS2323 3724-ST...