MAINTENANCE_MODE
It indicates if the device is available for maintenance. When the resource block is in AUTO
mode, MAINTENANCE_MODE parameter displays the text as 'Chk with Oper', that is
the device is in process and is not available for maintenance. When the resource block is in
OOS mode, MAINTENANCE_MODE parameter displays the text as 'Avail for Maint'
that is the device is out of process and is available for maintenance.
'Chk with Oper'- Check with operator to determine availability.
'Avail for Maint'- The device is available for maintenance.

Parameter List

Parameter
ST_REV
TAG_DESC
STRATEGY
ALERT_KEY
MODE_BLK
BLOCK_ERR
RS_STATE
TEST_RW
DD_RESOURCE
MANUFAC_ID
DEV_TYPE
DEV_REV
DD_REV
GRANT_DENY
HARD_TYPES
RESTART
FEATURES
Revision 2.0
FOUNDATION Fieldbus ST 700 Pressure Transmitter User's Guide

Table 6: Resource block parameters

The revision level of the static data associated with the function block.
The user description of the application of the block.
Used to identify grouping of blocks.
The identification number of the plant unit.
The actual, target, permitted, and normal modes of the block.
Reflects the error status associated with the hardware or software
components associated with a block. It is a bit string, so that multiple errors
may be shown.
Indicates the State of the function block application state machine.
Read/write test parameter is used only for conformance testing.
String identifying the tag of the resource, which contains the Device
Description for the resource.
Manufacturer identification number is used by an interface device to locate
the DD file for the resource.
Manufacturer model number associated with the resource. It is used by
interface devices to locate the DD file for the resource.
Manufacturer revision number associated with the resource. It is used by an
interface device to locate the DD file for the resource.
Revision of the DD associated with the resource. It is used by the interface
device to locate the DD file for the resource.
Options for controlling access of host computer and local control panels to
operating, tuning and alarm parameters of the block.
The types of hardware available as channel numbers. The supported
hardware type is SCALAR_INPUT.
Allows a manual restart to be initiated.
Used to show supported resource block options. The supported features
are: REPORT, SOFT_WRITE_LOCK, HARD_WRITE_LOCK, and
MULTI_BIT_ALARM.