Rs232-05 Accessory; Connector Pin Function; Indications; Connection With The Network - WEG CFW-11 User Manual

Anybus-cc
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

2.6
RS232
2.6.1

RS232-05 Accessory

Connector Pin Function

The RS232 communication module presents a male DB9 connector with the following pin assignment:

Indications

PWR LED: Green LED. When on, it indicates that the module is powered.

Connection with the Network

For the connection of the device using the passive RS232 interface, the following points must be observed:
Use good quality cables, preferably shielded.
Keep the cable length within the limits stipulated by the standard, normally about 10m.
Avoid passing the cables close to power cables.
2.7
RS485
2.7.1

RS485-05 Accessory

Connector Pin Function
The RS485/422 interface module presents a female DB9 connector with the following pin assignment:
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
WEG part number: 11008160.
Composed by the Anybus ABCC-RS232 communication
module, mounting instructions and a "torx" screw driver for
fixing the module.
It allows transmission rates up to 57.6 kbps.
Table 2.24: RS232 DB9 male connector pin assignment
Pin
Name
1
-
2
RxD
RS232 data reception
3
TxD
RS232 data transmission
4
-
5
GND
Reference (0 V) of the interface
6
-
7
RTS
Request To Send
8
-
9
-
WEG part number: 11008161.
Composed by the Anybus ABCC-RS485, mounting instructions
and a "torx" screw driver for fixing the module.
It allows transmission rates up to 57.6 kbps.