MODBUS TCP

2.4.1

MODBUSTCP-05 Accessory

Connector

The Modbus TCP communication module has a standard female RJ45 connector (T-568A or T-568B).

Indications

Modbus TCP defines two LEDs for status indication: one for the communication module (MS) and another for
the network (NS).
The MS LED indicates the conditions of the module itself. That is, whether it is able to work or not. Table 2.14
shows the possible states:
LED Status
Off
Green
Red
Flashing red
Flashing green/red
The NS LED indicates the conditions of the Modbus TCP network.
LED Status
Off
Green
Flashing green
Red
Flashing red
Flashing green/red
The LINK LED indicates the state of the physical connection of the network, as well as the activity in the bus.
LED Status
Off
Green
Flashing green
2.4.2

Installation of the Ethernet Network

For the connection of the frequency inverter using the Ethernet interface, refer to item 2.3.2.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
WEG part number: 11550476.
Composed by the Anybus ABCC-EIT communication module,
mounting instructions and a "torx" screw driver for fixing the
module.
Standard RJ45 connector.
Table 2.14: Status of the Modbus TCP module
Description
Without power supply
Normal operation
Serious fault.
Recoverable fault or conflict of IP
address
Equipment performing self-diagnosis
Table 2.15: Status of the Modbus TCP network
Description
Without power supply or IP address
Module is in Process Active or Idle state
Waiting for connections
Major fault or conflict of IP address
Timeout
Equipment performing self-diagnosis
Table 2.16: Status of the connection
Description
Without link
Link
Activity in the bus
Comments
Internal error of the module. Equipment must be
reinitialized.
Internal error of the module, but the return to the
normal state occurs automatically after the cause of
the fault is corrected.
Check the IP addresses in the network.
It occurs during initialization.
The software IPconfig must be used to configure the
communication module address.
Equipment must be reinitialized to exit the fault state.
Check the IP addresses in the network.
The data exchange has been interrupted.
It occurs during initialization.
Comments
Without connection, without activity
Ethernet link established but without data exchange
between master and slave.
It effectively indicates that there is data exchange
between the master and the slave.
-
-