Bits
Bits 0 to 3
Bit 4
Active quick stop
Bit 5
Second ramp
Bit 6
In configuration mode
Bit 7
Alarm condition
Bit 8
Motor Running
Bit 9
Active General Enable
Bit 10
Speed direction
Bit 11
JOG
Bit 12
LOC/REM
Bit 13
Undervoltage
Bit 14
Manual/ Automatic
Bit 15
Fault condition
P0681 – MOTOR SPEED IN 13 BITS
Range:
- 32768 to 32767
Properties:
RO
Access groups
via HMI:
Description:
It allows monitoring the motor speed. This word uses 13-bit resolution with signal to represent the motor
synchronous speed:
P0681 = 0000h (0 decimal)
P0681 = 2000h (8192 decimal)
Intermediate or higher speed values in rpm can be obtained by using this scale. E.g. for a 4 pole motor and
1800 rpm of synchronous speed if the value read is 2048 (0800h), then, to obtain the speed in rpm one must
calculate:
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Table 3.2: P0680 parameter bit functions
1: The drive is executing the fast stop command.
0: The drive is configured to use the first ramp values, programmed in P0100 and P0101, as the motor
1: The drive is configured to use the second ramp values, programmed in P0102 and P0103, as the motor
1: The drive is in the configuration mode. It indicates a special condition during which the drive cannot be
Executing the flash memory card self-guided routine
Note: The alarm number can be read by means of the parameter P0048 – Present Alarm.
1: The drive is running the motor at the set point speed, or executing either the acceleration or the
1: General Enable is active and the drive is ready to run the motor.
0: The motor is running in the reverse direction.
1: The motor is running in the forward direction.
Note: The fault number can be read by means of the parameter P0049 – Present Fault.
01 PARAMETER GROUPS
49 Communication
111 Status / Commands
→ motor speed = 0
→ motor speed = synchronous speed
Values
Reserved.
0: The fast stop command is not active.
acceleration and deceleration ramp times.
acceleration and deceleration ramp times.
0: The drive is operating normally.
enabled:
Executing the self-tuning routine
Executing the oriented start-up routine
Executing the HMI copy function
There is a parameter setting incompatibility
There is no power at the drive power section
0: The drive is not in alarm condition.
1: The drive is in alarm condition.
0: The motor is stopped.
deceleration ramp.
0: General Enable is not active.
0: Inactive JOG function.
1: Active JOG function.
0: Drive in Local mode.
1: Drive in Remote mode.
0: No Undervoltage.
1: With Undervoltage.
0: PID in manual mode.
1: PID in Automatic mode.
0: The drive is not in a fault condition.
1: The drive has detected a fault.
Default: -