2.8
FITTING THE FLUE TERMINAL
Fig. 14
a)
Position the flue terminal over the flue.
b)
Drill 3 off 3.5mm diameter holes in relation to the holes in the terminal.
c)
Secure the terminal to the outer flue with the 3 screws provided.
NOTE:
In England & Wales, the building regulations require that a terminal guard
should be fitted if the terminal could come into contact with people near the
building or are subject to damage. BFM Europe Ltd. also recommend the
fitting of a flue terminal guard where regulations do not demand that it be
fitted.
2.9
FITTING THE OPTIONAL TERMINAL GUARD
With the flue terminal in position, place the terminal guard over the top of the flue terminal
ensuring that the flue terminal is central. Mark the position of the holes on the outer wall.
Remove the terminal guard and drill the 4 off holes. Insert the raw plugs into the drilled
holes, replace the terminal guard over the top of the flue terminal and screw to the wall.
(See fig 15).
19