Fitting The Terminal Guard - Flavel Emberglow FEBC00MN Installation And Maintenance Instructions Manual

Coal effect balanced flue gas fire
Table of Contents

Advertisement

b)
Fit the rawlplugs into the 6mm holes.
c)
Clip the cooler plate into the bottom central fixing and into the left hand
and right hand mouning brackets (the same brackets used in section d)
below)
d)
The mounting brackets are attached to the rear of the combustion
chamber, position the product against the mounting wall and using a
long philips screwdriver, secure the 2 off screws into the wall behind the
product.
NOTE :
In England & Wales, the building regulations require that a terminal
guard should be fitted if the terminal could come into contact with people
near the building or be subject to damage. CFM Europe also recommend the
fitting of a flue terminal guard where regulations do not demand that it be
fitted. A suitable flue terminal guard can be obtained from CFM Europe Ltd.
quoting part no. 70-46560
2.7
FITTING THE OPTIONAL EXTRA TERMINAL GUARD
With the flue terminal in position, place the terminal guard over the top of the flue
terminal and mark the position of the holes on the outer wall. Remove the terminal
guard and drill the 4 off 6 mm holes. Insert the rawl plugs into the drilled holes,
replace the terminal guard over the top of the flue terminal and attach to the wall
using the No.12 x 40mm screws provided with the terminal guard. See Fig. 9
below.
Fig. 9