Cook/Filter Switch; Hi-Limit Control - Broaster 1600 Service Manual

Pressure fryer
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

COOK/FILTER SWITCH

1. See ACCESS FOR SERVICE.
2. Check all terminals and connections.
Refer to wiring diagram.
3. With needle nose pliers, disconnect
center terminal from switch.
4. Turn switch to COOK.
5. Check across center terminal and
lower terminal with an ohmmeter.
Meter should indicate a closed circuit.
If not, switch is faulty.
6. Turn switch to FILTER. Check across
center terminal and upper terminal.
Meter should indicate a closed circuit.
If not, switch is faulty.
Replacement:
1. See ACCESS FOR SERVICE.
2. Note where wires are connected. With
needle nose pliers, remove all wires
from switch (1).
3. Loosen hex nut (9) on rear of control
panel. Remove small knurled nut (10)
from front of switch.
4. Install new switch in reverse order. Be
sure small groove in threaded portion
of switch is down. Be sure all wire con-
nections are secure and in the original
location.

HI-LIMIT CONTROL

When controller opens, all controls are dis-
abled except the filter motor.
There are two ways to determine if the con-
trol is faulty:
4-9
broaster.com Manual #14680 3/99 Rev 5/14
Control open at cooking temperature.
Check cooking oil temperature 1 inch
below oil surface in center of cooking
well.
Electricity cannot travel across faulty
points.
1. See ACCESS FOR SERVICE.
2. Fully depress red reset button then
release.
3. With needle nose pliers, disconnect
one wire from control.
4. Check across two terminals with an
ohmmeter. Meter should indicate a
closed circuit. If not, control is faulty.

Advertisement

Table of Contents
loading

This manual is also suitable for:

1800

Table of Contents