Be sure red and yellow
wires are not reversed
during replacement. Controller will dis-
play PROB if polarity is reversed.
7. Disconnect transformer wires within
wire nuts.
8. Remove controller.
9. Assemble in reverse order.
10. See CALIBRATION.
TEMPERATURE SENSOR PROBE
This probe is a thermocouple. It sends fluc-
tuating millivolts to the controller which is
translated into degrees of temperature.
Replacement 1600/1800E:
1. See ACCESS FOR SERVICE.
2. Disconnect probe (18) wires.
3. OPEN cover. Drain cooking oil from
cooking well. Close drain valve.
4-12
broaster.com Manual #14680 3/99 Rev 5/14
4. Remove capillary guard (13) inside of
cooking well.
5. Remove basket guides (22) inside of
cooking well.
6. With a dull tool such as a crescent
wrench handle, pry top heating ele-
ment inward far enough to slide
bracket (21) away from temperature
sensor probe (19). Note where probe
bracket is located. Placement is
important.