Transformer (1800Gh) - Broaster 1600 Service Manual

Pressure fryer
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

1800GH Pressure Fryer:

TRANSFORMER (1800GH)

The transformer (20) supplies power to the
gas control valve.
1. See ACCESS FOR SEVICE.
5-7
broaster.com Manual #14680 3/99 Rev 5/14
2. Disconnect one wire from the primary
(black and white wires) side and sec-
ondary (yellow and blue wires) side of
the transformer.
3. Check between the two primary wires
with an ohmmeter. Meter should indi-
cate a closed circuit, If not, trans-
former is faulty.
4. Check between the two secondary
wires with an ohmmeter. Meter should
indicate a closed circuit. If not, trans-
former is faulty.