1800Gh Main Burner System; Model 1800Gh Lighting Instructions; Gas Conversion; High Altitude - Broaster 1600 Service Manual

Pressure fryer
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

9 - 1800GH MAIN BURNER SYSTEM

MODEL 1800GH LIGHTING
INSTRUCTIONS
Start Up:
1. Turn cook/filter switch OFF.
2. See OIL LEVEL in the operation man-
ual.
3. Turn gas shut-off valve (1) ON. Wait
five minutes before turning gas control
ON.
4. Slide switch (2) on top of gas valve to
ON.
The Model 1800GH has
an intermittent pilot
burner. This type of pilot lights when the
controller calls for heat and goes out
when the controller is not calling for
heat.
5. To light pilot and main burners, turn
cook/filter switch to COOK.
Shut Down:

GAS CONVERSION

To convert from one type of gas to another,
five components must be changed: gas
valve, pilot burner orifice, main burner ori-
fice and gas data plate. Notify the Broaster
Company Service Department of a conver-
sion in writing.
Main Burner Orifice Sizes Up To 2000
Feet Above Sea Level:

HIGH ALTITUDE

Standard gas units operate up to 2000 feet
above sea level. Installations above this
require a special main burner orifice. Con-
tact the Broaster Company for orifice sizing.
9-1
broaster.com Manuals #14680 3/99 Rev 5/14
1. Turn cook/filter switch OFF.
2. Turn gas valve switch (2) OFF.
3. Turn gas shut-off valve (1) OFF.
Natural Gas: #24
Propane: #41

Advertisement

Table of Contents
loading

This manual is also suitable for:

1800

Table of Contents