Ventilation; Gas Valve - Broaster 1600 Service Manual

Pressure fryer
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

VENTILATION

• Never modify exhaust flue! Back pres-
sures from added extensions can cause
high ambient temperatures near the
controls.
• Make sure unit is correctly ventilated.
Restrictions, drafts or other adverse
conditions might affect proper operation
of the burner and combustion assem-
blies.

GAS VALVE

Regulates gas supply. The gas valve has a
two position switch: OFF to stop all gas
flow, and ON allows gas flow to pilot and
main burners as needed. Adjustment for
gas pressure and gas flow to pilot burner
are also found on the valve.
Replacement:
Continued:
9-2
broaster.com Manuals #14680 3/99 Rev 5/14
1. Turn cook/filter switch, manual gas
shut off valve (1) and switch (2) OFF.
2. Turn main gas supply OFF.
3. Disconnect main electric supply.
4. Remove condensate pan and front
panel.
5. Disconnect gas valve wire harnesses
(3).
6. Loosen fitting (4) that mounts pilot
burner gas supply line to gas valve.
7. Loosen brass union nut (5).
8. Loosen pipe union (6).
9. Remove piping from gas valve.

Advertisement

Table of Contents
loading

This manual is also suitable for:

1800

Table of Contents