VENTILATION
• Never modify exhaust flue! Back pres-
sures from added extensions can cause
high ambient temperatures near the
controls.
• Make sure unit is correctly ventilated.
Restrictions, drafts or other adverse
conditions might affect proper operation
of the burner and combustion assem-
blies.
GAS VALVE
Regulates gas supply. The gas valve has a
two position switch: OFF to stop all gas
flow, and ON allows gas flow to pilot and
main burners as needed. Adjustment for
gas pressure and gas flow to pilot burner
are also found on the valve.
Replacement:
Continued:
9-2
broaster.com Manuals #14680 3/99 Rev 5/14
1. Turn cook/filter switch, manual gas
shut off valve (1) and switch (2) OFF.
2. Turn main gas supply OFF.
3. Disconnect main electric supply.
4. Remove condensate pan and front
panel.
5. Disconnect gas valve wire harnesses
(3).
6. Loosen fitting (4) that mounts pilot
burner gas supply line to gas valve.
7. Loosen brass union nut (5).
8. Loosen pipe union (6).
9. Remove piping from gas valve.