EXHAUST DRAIN TUBE

Tube (1) drains condensation from exhaust
tank into the condensate pan.

EXHAUST TANK

Steam and vapors are exhausted through
this tank.
See previously mentioned operator habits.
Tank (2) can become obstructed. The
obstruction usually forms where exhaust
drain tube (1) meets tank. Tank will then
become filled with liquid. Liquid may be
forced up the stack (3) when pressure is
released at the end of a cooking cycle.
Cleaning:
7-2
broaster.com Manual #14680 3/99 Rev 5/14
1. Remove two screws, cover (4) and
seal (5) from tank.
2. Scrape inside of tank clean.
3. Replace seal (5) and grommet (6) if
necessary.
4. Assemble in reverse order.