7. Rotate cover handle to the CLOSED
position.
8. Align holes in lifter box, spacer block
and cover.
9. Install new cover bolts but do not
tighten.
10. Install slide rod through bearings on
right hand side of yoke bar.
11. Place assembly onto counter top.
Place slide rod (13) into the rear sup-
port, install bolt into front of the slide
rod and install bolt on back of slide rod
(1600).
12. Pull cover forward. If yoke latch (6)
and latch columns (7) do not line up,
adjust slide rod (13) to the left or right.
13. Center cover within the cooking well.
See Centering Cover.

PRESSURE GAUGE

Gauge indicates pressure within the cook-
ing well. Operating pressure is 12-14 PSI.
Replacement:
6-6
broaster.com Manual #14680 3/99 Rev. 5/14
1. OPEN the pressure regulating valve
then the cover.
2. Unscrew gauge (15) from the elbow
(16).
3. Use teflon tape on the threads. Screw
new gauge onto the elbow.