M30870T-EPB User's Manual
2.4 Connecting the PC7501
Figure 2.3 shows how to connect the PC7501 and the emulation probe.
Figure 2.3 Connecting the PC7501 and emulation probe
Cautions for Connecting the PC7501:
When connecting the emulation probe, be sure to hold the both sides of the emulation probe horizontally and
insert it directly.
Connect the PCA7501EPBA board to the M3T-FLX160-EPB.
Always shut OFF power before connecting the emulation probe. Otherwise, internal circuits may be damaged.
REJ10J0482-0300 Rev.3.00 February 16, 2006
Note: Connect the PCA7501EPBA board side to the M3T-FLX160-EPB.
CAUTION
M3T-FLX160-EPB
M30870T-EPB
2. Setup
Page 22 of 104