5
HEATING-COOLING TEMPERATURE CONTROL MODULE/TEMPERATURE

5.5.4 A1S62TCTT(BW)-S2/A1S62TCRT(BW)-S2 and L series modules

Address (hexadecimal)
CH1
1
5
9
D
11
15
19
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
*1
For the A1S62TCRT(BW), this area is prohibited to use.
*2
For the L60TCRT(BW), this area is prohibited to use.
5
- 61
A1S62TCTT(BW)-S2, A1S62TCRT(BW)-S2
CH2
0
Write data error code
2
Decimal point position
6
Alert occurrence details
A
Temperature process value (PV)
E
Heating manipulation value (MV)
12
Increased temperature determination flag
16
Heating transistor output flag
1A
Heater current process value
1D
Cooling contact temperature process value
1E
System area (Use prohibited)
1F
40
Input range
41
Stop mode setting
42
Set value (SV) setting
43
Heating proportional band (Ph) setting
44
Integral time (I) setting
45
Derivative time (D) setting
46
Alert set value 1
47
Alert set value 2
48
Alert set value 3
49
Alert set value 4
4A
Heating-cooling upper limit output limiter
4B
System area (Use prohibited)
4C
4D
Sensor correction value setting
4E
System area (Use prohibited)
4F
Heating control output period setting
50
Primary delay digital filter setting
51
Control response parameter
52
System area (Use prohibited)
53
54
Setting change rate limiter
55
System area (Use prohibited)
56
57
Upper limit setting limiter
58
Lower limit setting limiter
59
CT selection
5A
Heater wire breakage alert setting
5B
System area (Use prohibited)
5C
5D
Not used channel setting
Name
*1
Read/write
R/W
R
R/W