Current Ratings - Iec Non Regenerative - ABB DCS880 series Hardware Manual

20 ... 5200 a
Hide thumbs Also See for DCS880 series:
Table of Contents

Advertisement

50

Current ratings - IEC non regenerative

See the current ratings including several standard duty cycles for the DCS880 with 50 Hz and 60 Hz
supplies below. The current ratings are based on an ambient temperature of maximum 40°C and an
elevation of maximum 1000 m above mean sea level:
Unit type
2-Q converters
400 V / 500 V / 525 V
DCS880-S01-0020-04/05**
DCS880-S01-0045-04/05**
DCS880-S01-0065-04/05**
DCS880-S01-0090-04/05**
DCS880-S01-0135-04/05
DCS880-S01-0180-04/05**
DCS880-S01-0225-04/05
DCS880-S01-0270-04/05
DCS880-S01-0315-04/05**
DCS880-S01-0405-04/05**
DCS880-S01-0470-04/05
DCS880-S01-0610-04/05**
DCS880-S01-0740-04/05
DCS880-S01-0900-04/05
600 V / 690 V
DCS880-S01-0290-06
DCS880-S01-0590-06
** This unit type can be used as large field exciter. Do not forget the SDCS-DSL-H1x (+S199).
A 10 % current de-rating is strongly recommended.
Notes:
AC current I
1190 A
Technical data
I
DC I
continu-
100 %
ous
15 min
[A]
20
45
65
90
135
105
180
130
225
170
270
200
315
240
405
310
470
350
610
455
740
570
900
680
290
240
590
470
= 0.82 * I
AC
DC
for 35°C and 1140 A
DC
DC
3ADW000462R0101 DCS880 Hardware Manual e a
I
I
DC II
DC III
150 %
100 %
60 s
15 min
[A]
[A]
16
24
16
36
54
35
54
81
52
76
114
74
157
100
195
125
255
165
300
195
360
235
465
300
525
340
682
435
855
540
1020
650
360
225
705
472
for 40°C ambient temperature
I
DC IV
150 %
100 %
200 %
120 s
15 min
10 s
[A]
24
15
30
52
31
62
78
49
98
111
73
146
150
93
186
187
110
220
247
148
296
292
180
360
352
215
430
450
270
540
510
310
620
652
425
850
810
525
1050
975
615
1230
337
205
410
708
434
868
Internal
Size
field current
0.3 ... 6 A
H1
1 ... 12 A
H2
1 ... 18 A
H3
2 ... 25 A
H4
2 ... 30 A
H3
-
H4
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcs880-s series