Ssi Connection; Positioning - Dimetix DLS-C 15 Technical Reference Manual

Distance laser sensor dls-c series fls-c series
Hide thumbs Also See for DLS-C 15:
Table of Contents

Advertisement

T
R
ECHNICAL

2.5 SSI connection

SSI master
shielded twisted pair
(i.e. controller)
connection
Cloc k+
Cloc k-
SSI c lock
Data+
Data-
Shield
SSI data
Fig. 6: SSI connection example

2.6 Positioning

Possition
Fig. 7: Positioning application
Distance Laser Sensor
M
EFERENCE
ANUAL
SSI slave
FLS-C(H)
R+
6
(SSI Cloc k in +)
R-
5
(SSI Cloc k in -)
4
T+
(SSI data out +)
T-
3
(SSI data out -)
7, 8
V+
Vc c
14 , 15
0V
GND
Set the FLS-C(H) in stand-alone mode (3.3.2 Stand-alone mode on page 11) and
connect it to a SSI master as shown in Fig. 6. The measured distances are
immediately available at the SSI output. See 9.3.10 Interface 2 configuration (RS-
422 / SSI) on page 39 for the detailed command description.
Never connect the SSI master before the FLS-C(H) interface 2 is configured as SSI
interface.
The figure on the left shows a typical positioning application. In this
application the SSI interface of the FLS-C(H) is directly connected to a
position input of a motor drive. The drive controls the motor In such a
way, that the sledge moves to the position given as set point by the
PLC.
The encoder is used for security reasons to double check the movement
by the Drive.
In this applications the FLS-C(H) uses the SSI interface (4.2.6 SSI
connection on page 19) and the moving target characteristic (3.4.2
Moving target characteristic on page 13.
Please check on
www.dimetix.com
for detailed application notes.