3.4 Measuring characteristics

Multiple measuring characteristics are available in the FLS-C measuring devices to meet different requirements for various applications. With
these measuring characteristics measuring rate and accuracy can be optimized for special requirements.
The FLS-C measuring device at factory settings has an accuracy of ±1 mm (FLS-C(H) 10) respectively ±3 mm (FLS-C(H) 30) at 2σ. Measuring
rate depends on environmental conditions such as target surface, distance, background light (e.g. sun light), etc. Good environmental
conditions increase measuring rate (e.g. white target surface or orange reflective target plate and dark environment).

3.4.1 Measuring characteristics overview

Measuring
Measuring
character-
rate
istic
Normal
max. 10
(factory
Hz
3)1)
setting)
Fast
max. 20 Hz
1)
Precise
max. 6 Hz
1)
~±0.8 mm ~±2.4 mm
max. 6Hz,
can drop to
Natural
0.25Hz @ up
surface
to approx.
80m
user
programmed
Timed
DLS: ≤ 6Hz,
FLS: ≤ 35Hz
250Hz,
Moving
SSI can poll
Target
with up to
500Hz
1) The behavior in case of an error depends on the configuration. See 3.4.3 Error behavior on page 14
2) Changed characteristics do not influence all commands
3) Good environmental conditions (e.g. white target surface or orange reflective target plate and dark environment).
4) For the description of the command see 9.3.2 Measuring characteristic configuration (sNuc) on Page 34
Distance Laser Sensor
M
EFERENCE
ANUAL
Typical accuracy @
FLS-C(H)
FLS-C(H)
10
30
Measuring range on natural surface: typical 65 m
±1 mm
±3 mm
Configuration command: sNuc+0+0
Increased measuring rate up to 20 Hz.
±2 mm
±6 mm
Configuration command: sNuc+0+1
Increased accuracy of ±0.8 mm
Surveying applications, short range applications etc.
Configuration command: sNuc+0+2
Increased measuring range on natural surfaces:
~±5 mm
~±15 mm
typical 80 meters
@ up to
@ up to
Measuring against far away natural surfaces or bad reflective
approx.
approx.
surfaces such as black synthetic granules, etc.
80m
80m
Configuration command: sNuc+0+3
The device does not check the signal condition to ensure the
specified accuracy is reached, a measurement value is transferred
to the output at a defined measuring rate.
variable
variable
This mode serves for applications where the accuracy is not
important but the reaction time is critical
Configuration command: sNuc+1+1
The device measures to a continuously moving target and the
distance changes without any jumps.
This measurement characteristic supervises the max speed,
checks for distance jumps and includes a special filter to
±1 mm
±3 mm
eliminate errors occurring for only a very short time.
Configuration command: sNuc+2+0
Description
4)
4)
4)
4)
4)
4)
(with error freezing)
4)
sNuc+2+1
(without error freezing)
Available in DLS-C(H)
Available in FLS-C(H)
Error behavior
1)
User Commands
2)
Normal Commands
2)
 
 
 
 
 
 
 
A
 
A
 
A
 
A
 
A
 
B
Page 12/53