Sign In
Upload
Manuals
Brands
Dimetix Manuals
Measuring Instruments
DLS-CH 15
Dimetix DLS-CH 15 Manuals
Manuals and User Guides for Dimetix DLS-CH 15. We have
3
Dimetix DLS-CH 15 manuals available for free PDF download: Technical Reference Manual
Dimetix DLS-CH 15 Technical Reference Manual (53 pages)
Distance Laser Sensor DLS-C series FLS-C series
Brand:
Dimetix
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Product Identification
5
Components
5
Validity
5
2 Application Examples
6
Serial Interface RS-232 / RS-422
6
Analog and Digital Output
6
External Display
6
External Trigger
6
SSI Connection
7
Positioning
7
3 Device Overview and Setup
8
Connection for Configuration
8
Output Interfaces
9
Output Configuration Example
9
Operation Modes
10
Controlled Mode
10
Stand-Alone Mode
11
Measuring Characteristics
12
Measuring Characteristics Overview
12
Moving Target Characteristic
13
Error Behavior
14
Special User Commands
15
Offset / Gain
15
Output Format
15
Output Value Filter
16
Moving Average Filter
16
Spike Suppression Filter
16
Error Suppression Filter
16
4 Installation
17
Mounting
17
Mounting of the Device
17
Mounting for the Reflective Plate
17
Alignment of the Laser Beam
17
Laser Life Time Consideration
17
Device Wiring
17
Power Supply
17
Cable Connection
17
Shield and Ground
17
Serial Connection
18
Analog / Digital Connection
19
SSI Connection
19
External Trigger Connection
20
5 Technical Data
21
Measuring Accuracy Definition
21
Measuring Performance Influences
21
Prevention of Erroneous Measurements
22
Rough Surfaces
22
Transparent Surfaces
22
Wet, Smooth, or High-Gloss Surfaces
22
Inclined, Round Surfaces
22
Multiple Reflections
22
Influence of Sun Light
22
Specifications
23
Dls-C 15 / Dls-C
23
6 Electrical Components
24
ID Switch
24
Reset Switch
24
Digital Output
24
Digital Input
24
Analog Output
25
RS-232 Serial Interfaces
25
RS-422 Serial Interface
25
SSI Output
26
SSI Specification
26
SSI Timing
26
Connector
27
D-Sub Connector
27
Screw Terminal
27
Technical Reference Manual
27
7 Physical Dimensions
28
8 Factory Settings
28
Standard Configuration
28
User Configured Measurement
28
9 Command Set
29
General
29
Command Termination <Trm
29
Device Identification N
29
Parameter Separator
29
Set/Get Commands
29
Startup Sequence
29
Operation Commands
30
Distance Measurement (Sng)
30
Single Sensor Tracking (Snh)
30
Single Sensor Tracking with Timer(Snh)
30
Tracking with Buffering - Start (Snf)
31
Read out - Tracking with Buffering(Snq)
31
STOP/CLEAR Command (Snc)
31
Signal Measurement (Snm)
31
Temperature Measurement (Snt)
32
Laser on (Sno)
32
Laser off (Snp)
32
Configuration Commands
33
Set Communication Parameter (Snbr)
33
Measuring Characteristic Configuration (Snuc)
34
Set Auto Start Configuration (Sna)
35
Set/Get Analog Output Min Level (Snvm)
35
Set/Get Analog Output Value in Error Case (Snve)
35
Set/Get Analog Output Distance Range (Snv)
36
Set/Get Digital Output Levels (Snn)
37
Configure Digital Input (Sndi1)
38
Read Digital Input (Snri)
38
Interface 2 Configuration (RS-422 / SSI)
39
Set/Get Error Value on SSI Output
40
Set/Get Measurement Filter Configuration (Snfi)
40
Save Configuration Parameters (Sns)
40
Set Configuration Parameters to Factory Default (Snd)
41
Get Software Version (Snsv)
41
Get Serial Number (Snsn)
41
Get Device Generation and Type (Dg)
42
Get Device Type (Dt)
42
Special User Operation Commands
43
User Distance Measurement (Snug)
43
User Single Sensor Tracking (Snuh)
43
User Single Sensor Tracking with Timer(Snuh)
44
User Tracking with Buffering - Start (Snuf)
44
Read out - User Tracking with Buffering (Snuq)
44
Special User Configuration Commands
45
Set User Auto Start Configuration (Snua)
45
Set/Get User Distance Offset (Snuof)
45
Set/Get User Distance Gain (Snuga)
45
User Output Protocol (Snuo)
46
Error Codes
47
10 Safety Instructions
48
Use of the Instrument
48
Limits to Use
48
Areas of Responsibility
49
Hazards in Use
49
Laser Classification
50
Electromagnetic Compatibility (EMC)
51
Producer Standards
51
Disposal
51
Labeling
52
Laser Specification
52
Maintenance
52
Service
52
Advertisement
Dimetix DLS-CH 15 Technical Reference Manual (42 pages)
Distance Laser Sensor
Brand:
Dimetix
| Category:
Analytical Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Product Identification
6
Components
6
Validity
6
Measuring Range
7
Prevention of Erroneous Measurements
7
Rough Surfaces
7
Transparent Surfaces
7
Wet, Smooth, or High-Gloss Surfaces
7
Inclined, Round Surfaces
7
Multiple Reflections
7
2 Device Setup
8
Connection
8
Controlled Mode
9
Configuration
9
Host Software
9
Automatic Mode
10
Configuration
10
Display Mode
11
External Trigger
11
Configuration
11
3 Installation
12
Mounting
12
Device Wiring
12
Power Supply
12
Cable Connection
12
Shield and Ground
12
Controlled Mode
13
Automatic Mode
14
Alignment of the Laser Beam
14
4 Technical Data
15
Measuring Accuracy
15
Specifications
16
5 Electrical Components
17
ID Switch
17
Reset Switch
17
Digital Output
17
Digital Input
17
Analog Output
17
Connector
18
D-Sub Connector
18
Screw Terminal
18
6 Physical Dimensions
19
7 Factory Settings
20
Operation
20
Communication Parameters
20
Analog Outputs
20
Module ID
20
Digital Output 1 (DOUT1)
20
Digital Output 2 (DOUT2)
20
Digital Input 1 (DI1)
20
User Distance Offset
20
8 Command Set
21
General
21
Command Termination <Trm
21
Module Identification N
21
Parameter Separator
21
Set/Get Commands
21
Startup Sequence
21
Operation Commands
22
STOP/CLEAR Command (Snc)
22
Distance Measurement (Sng)
22
Signal Measurement (Snm)
22
Temperature Measurement (Snt)
22
Laser on (Sno)
23
Laser off (Snp)
23
Single Sensor Tracking (Snh)
24
Tracking with Buffering - Start (Snf)
24
Read out - Tracking with Buffering(Snq)
24
Configuration Commands
25
Set/Get Communication Parameter (Snbr)
25
Enhanced Measuring Modes (Snuc)
26
Set Automatic Mode (Sna)
27
Set/Get Analog Output Min Level (Snvm)
27
Set/Get Analog Output Value in Error Case (Snve)
27
Set/Get Distance Range (Snv)
28
Set/Get Digital Output Levels (Snn)
29
Save Configuration Parameters (Sns)
29
Set Configuration Parameters to Factory Default (Snd)
30
Get Software Version (Snsv)
30
Get Serial Number (Snsn)
30
Get Device Generation and Type (Dg)
30
Digital Input
31
Configure Digital Input (Sndi1)
31
Read Digital Input (Snri)
31
SSI (Synchronous Serial Interface)
32
Change from RS422 to SSI Output and Back
32
Set/Get Error Value on SSI Output
32
Special User Commands
33
Set/Get User Distance Offset (Snuof)
33
User Configured Distance Measurement (Snug)
33
User-Configured Single Sensor Tracking (Snuh)
34
User-Configured Tracking with Buffering - Start (Snuf)
34
Read out - User-Configured Tracking with Buffering (Snuq)
35
Error Codes
36
9 Safety Instructions
37
Use of the Instrument
37
Limits to Use
37
Areas of Responsibility
38
Hazards in Use
38
Laser Classification
39
Electromagnetic Compatibility (EMC)
40
Producer Standards
40
Disposal
40
Labeling
41
Laser Specification
41
Maintenance
41
Service
41
Dimetix DLS-CH 15 Technical Reference Manual (71 pages)
long range laser distance sensor
Brand:
Dimetix
| Category:
Measuring Instruments
| Size: 1 MB
Advertisement
Advertisement
Related Products
Dimetix DLS-C 15
Dimetix DLS-C 30
Dimetix DLS-B 15
Dimetix DLS-BH 15
Dimetix DLS-B 30
Dimetix DLS-BH 30
Dimetix DLS-A 15
Dimetix DLS-A 30
Dimetix DLS-AH 15
Dimetix DLS-AH 30
Dimetix Categories
Measuring Instruments
Accessories
Security Sensors
Analytical Instruments
More Dimetix Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL