T
R
ECHNICAL
7 Physical dimensions
37.3
Laser Beam
19.0
80.0
All dimensions in mm
8 Factory settings
8.1 Standard configuration
Operation Mode
Serial Communication
Analog outputs
SSI Output
Device ID
Digital output 1 (DOUT1)
Digital output 2 (DOUT2)
Digital input 1 (DI1)
8.2 User configured measurement
User distance offset and gain
Measurement characteristic
Measurement Filter
Output protocol
Distance Laser Sensor
M
EFERENCE
ANUAL
12.2
Controlled
Setting 7
Min output:
Error output:
Inactive (default is RS-422 active)
Replacement value in case of an error:
ID Number:
ON:
OFF: 2m - 5mm
ON:
OFF: 1m + 5mm
Inactive, configured as output
User distance offset =
User Gain Num
User Gain Den
Normal
inactive
No special configuration, display distance
88.5
38.5
150.0
152.5
Measuring reference
Baud:
19200
Data bit:
7
4mA
0mA
0
2m + 5mm
=
2005mm
=
1995mm
1m – 5mm
=
995mm
=
1005mm
0mm
=
Gain=
=
3 x M4 x 5
M16 x 1.5
Parity:
Even
Stop bit:
1
Range min:
0m
Range max:
10m
0
GainNum
1000
User
=
=1
GainDen
1000
User
1000
1000
Page 28/53