2 Application examples

Since the configuration of the DLS-C(H)/FLS-C(H) is very flexible the device is usable in various situations. The following application examples
give an idea of possible applications. Please visit
check for additional application examples.

2.1 Serial interface RS-232 / RS-422

DLS-C(H)/FLS-C(H)
(slave)
ID switch
Position 0
Siemens S7
CP 340 Zusatzkarte
Sub-D
Pin 9
Buchse 15pol
Pin 2
Pin 11
Pin 4
Pin 8
Vcc
CP340-RS 422/485;
6ES7 340-1CH00-0AE0
0V
Fig. 2: RS-422 connection to S7 PLC

2.2 Analog and digital output

AO
13
AGND
12
DLS-C(H)
DO 1
9
FLS-C(H)
DO 2
10
V+
7,8
GND
14,15
Fig. 3: AO and DO connection

2.3 External display

Rx
1
Tx
2
GND
DLS-C(H)
14,15
FLS-C(H)
DO/DI 1
9
V+
7,8
Fig. 4: External display connection

2.4 External trigger

AO
13
AGND
12
DLS-C(H)
DO/DI 1
FLS-C(H)
9
V+
7,8
Fig. 5: Use digital input as external trigger
Distance Laser Sensor
M
EFERENCE
ANUAL
www.dimetix.com
DLS-C(H)/FLS-C(H)
DLS-C(H)/FLS-C(H)
(slave)
(slave)
ID switch
ID switch
Position 9
Position 1
24V=
9..30VDC
24..30VDC for Heating Option
0V
m
RS232 or RS422
1k
1k
for a detailed description of the mentioned application examples and
While the RS-232 should be used for the configuration of the device (See
3.1 Connection for configuration on page 8) the RS-422 is made for
communication in industrial environment (See 3.3.1 Controlled mode on
page 10 and 4.2.4 Serial connection on page 18).
Fig. 2 shows the connection of multiple DLS-C(H)/FLS-C(H) devices to a
Siemens S7 PLC. A detailed application note can be found on
www.dimetix.com.
For RS-422 connections use twisted pair cables only!.
Activate the stand-alone mode (3.3.2 Stand-alone mode on page 11) and the
device is ready to use. It starts measuring after power on and updates the analog
and digital output according to the configuration. See 9.3.4 and the following
chapters for the configuration commands.
If Display Mode is enabled, the DLS-C(H)/FLS-C(H) formats the measured distance
as ASCII string, which is understood by External Displays with a serial interface.
Since the DLS-C(H)/FLS-C(H) transfers this formatted string automatically on the
serial interface after completing a measurement. Measurement results can be
displayed on an external display without an additional controller.
Check
www.dimetix.com
for a detailed application note.
The DLS-C(H)/FLS-C(H) includes the option of triggering measurements with an
external switch or push button on Digital Input 1 (DI 1). Using the Digital Input DI 1
disables the Digital Output DO 1.
Please refer to 3.3.2.2 Manual start configuration on page 11
Page 6/53