9.3.6 Set/Get analog output distance range (sNv)

Sets the minimum and maximum distances corresponding to the minimum and maximum analog output current levels.
Aout=
Command
Return successful
Return error
Parameters
Configuration parameters need to be saved (See 9.3.13 Save configuration parameters (sNs) on page 40)
Distance Laser Sensor
M
EFERENCE
ANUAL
0...20mA
DIST −D
min
∗20mA
D
−D
max
min
Aout
Analog current output
DIST
Actual measured distance
D
min
Distance programmed for the minimum output current
D
Distance programmed for the maximum output current
max
Set command
sNv+xxxxxxxx+yyyyyyyy<trm>
gNv?<trm>
gN@Ezzz<trm>
N
Device ID
xxxxxxxx
Minimum distance in 1/10 mm corresponding to 0mA / 4mA
yyyyyyyy
Maximum distance in 1/10 mm corresponding to 20mA
zzz
Error code
4...20mA
DIST −D
min
Aout=
∗16mA +4mA
D
−D
max
min
Get command
sNv<trm>
gNv+xxxxxxxx+yyyyyyyy<trm>
gN@Ezzz<trm>