Configure Digital Input (Sndi1); Read Digital Input (Snri) - Dimetix DLS-C 15 Technical Reference Manual

Distance laser sensor dls-c series fls-c series
Hide thumbs Also See for DLS-C 15:
Table of Contents

Advertisement

T
R
ECHNICAL

9.3.8 Configure digital input (sNDI1)

The digital output 1 of the DLS-C(H)/FLS-C(H) can also be used as digital input. The command
The state of the digital input can be read with the command
On active digital input, the digital output function of DO1 is deactivated
Command
Return successful
Return error
Parameters
1) Uses time for the tracking as set by a previous
Configuration parameters need to be saved (See 9.3.13 Save configuration parameters (sNs) on page 40)

9.3.9 Read digital input (sNRI)

Displays the state of the digital input, if the input is not inactive. (Necessary configuration of the digital input: sNDI1+1)
Command
Return successful
Return error
Parameters
Distance Laser Sensor
M
EFERENCE
ANUAL
Set command
sNDI1+xxxxxxxx<trm>
gNDI1?<trm>
gN@Ezzz<trm>
N
Device ID
xxxxxxxx
0:
Digital input inactive (DO1 active)
1:
activate the digital input to read out its state with the command
9.3.9 Read digital input (sNRI).
2:
Trigger Distance measurement (sNg)
3:
Start/Stop Single sensor Tracking (sNh)
4:
Start/Stop Tracking with buffering (sNf)
5:
Trigger User Distance measurement (sNug)
6:
Start/Stop Single sensor User Tracking (sNuh)
7:
Start/Stop User Tracking with buffering (sNuf)
8:
Start/Stop Single sensor Timed Tracking (sNh+)
9:
Start/Stop Single sensor User Timed Tracking (sNuh+)
zzz
Error code
sNh+
or
Command
sNRI<trm>
gNRI+x<trm>
gN@Ezzz<trm>
N
Device ID
x
0: Input Off (Signal Low)
1: Input On (Signal High)
zzz
Error code
sNRI
.
sNDI1<trm>
sNDI1+xxxxxxxx<trm>
gN@Ezzz<trm>
sNuh+
command
sNDI1
configures an action for the device.
Get command
1)
1)
Page 38/53