Connector; D-Sub Connector; Screw Terminal; Technical Reference Manual - Dimetix DLS-C 15 Technical Reference Manual

Distance laser sensor dls-c series fls-c series
Hide thumbs Also See for DLS-C 15:
Table of Contents

Advertisement

T
R
ECHNICAL

6.9 Connector

6.9.1 D-Sub connector

15
9
8
1

6.9.2 Screw terminal

No.1
Distance Laser Sensor
M
EFERENCE
ANUAL
Pin
Designator
1
Rx
2
Tx
3
T-
4
T+
5
R-
6
R+
7
V+
8
V+
9
DO 1
10
DO 2
11
DO E
12
AGND
13
AO
14
GND
15
GND
Designator
R+
R-
T+
T-
Tx
Rx
AGND
AO
DO E
DO 2
DO 1
GND
V+
Description
RS-232 receive line
RS-232 send line
RS-422 send line negative
SSI data output negative (for FLS-C(H) if configured for SSI)
RS-422 send line positive
SSI data output positive (for FLS-C(H) if configured for SSI)
RS-422 receive line negative
SSI clock input negative (for FLS-C(H) if configured for SSI)
RS-422 receive line positive
SSI clock input positive (for FLS-C(H) if configured for SSI)
DC Power
+ 9V...+30V for DLS-C / FLS-C
+24V...+30V for DLS-CH / FLS-CH (Heating option)
Digital output 1 (Open Drain) or Digital input 1
Digital output 2 (Open Drain)
Digital output for error signalization (Open Drain)
Analog ground
Analog output (0/4..20mA)
Ground line
Ground line
Description
RS-422 send line negative
SSI data output negative (for FLS-C(H) if configured for SSI)
RS-422 send line positive
SSI data output positive (for FLS-C(H) if configured for SSI)
RS-422 receive line negative
SSI clock input negative (for FLS-C(H) if configured for SSI)
RS-422 receive line positive
SSI clock input positive (for FLS-C(H) if configured for SSI)
RS-232 Transmit line
RS-232 Receive line
Analog ground
Analog output (0/4..20mA)
Digital output for error signalization (Open Drain)
Digital output 2 (Open Drain)
Digital output 1 (Open Drain) or Digital input 1
Ground line
Power DC
+9V...+30V DLS-C / FLS-C
+24...+30V DLS-CH / FLS-CH (Heating option)