4 Installation

4.1 Mounting

4.1.1 Mounting of the device

Three M4 threaded holes in the bottom of the DLS-C(H)/FLS-C(H) make it easy to mount the device.
Always obey all applicable safety regulations and never use the device outside the specifications stated under 5 Technical data on page 21.

4.1.2 Mounting for the reflective plate

Sensor
Laser Beam
Reflective plate
Fig. 13: Reflective Plate mounting

4.1.3 Alignment of the laser beam

Alignment of the laser beam is often difficult when the target is far away, as the laser spot is not visible. An optional telescopic viewfinder
and an alignment jig is available to simplify the alignment procedure. (See

4.1.4 Laser Life time consideration

since the life time of the laser is limited, operate the device in a way, that the laser is switched on only when necessary. The laser life time
stated under 5 Technical data on page 21 relates to the time while the laser is on.

4.2 Device wiring

4.2.1 Power supply

For trouble-free operation use a separate power supply for the DLS-C(H)/FLS-C(H).
FLS-C, DLS-C:
FLS-CH, DLS-CH:

4.2.2 Cable connection

A ferrite core must be fitted to the connecting cable. Use a ferrite core with an impedance of 150 Ω to 260 Ω at 25MHz and 640 Ω to 730
Ω at 100MHz. For example you can use KCF-65 from KE Kitagawa.

4.2.3 Shield and ground

10nF
GND
AGND
Fig. 14 Connection between shield and ground
Distance Laser Sensor
M
EFERENCE
ANUAL
Measuring to the reflective plate may generate erroneous measurements, if the reflective plate is
1-3°
mounted exactly at an angle of 90° to the laser beam. Therefore mount the reflective plate like shown
in figure 13.
Avoid direct sunlight on the reflective plate to increase measurement performance.
9...30V, 0.5A DC
24...30V, 2.5A DC
DLS-C(H)
20nF
FLS-C(H)
Screw terminal
www.dimetix.com
for additional accessories and further details).
The DLS-C(H)/FLS-C(H) contains two electrically isolated grounds, the
general ground (GND) and the analog ground (AGND). GND and
AGND are connected to the housing by a RC element. Please see
figure 19.