9 Command set

9.1 General

9.1.1 Command termination <trm>
All commands for the DLS-C(H)/FLS-C(H) are ASCII based and terminated

9.1.2 Device identification N

Since the device can be addressed with the ID switch, the ID is represented in the commands by
N
At the location of the
insert the Device ID.

9.1.3 Parameter separator

The command syntax uses the '
command.

9.1.4 Set/Get commands

All configuration commands that are used to set configuration values can also be used to read the currently set value by omitting the
parameter. The command syntax is described as follows:
Command
Return successful
Return error
Parameters

9.1.5 Startup sequence

After power on, the DLS-C(H)/FLS-C(H) does all the initializations and sends a start sequence
Device ID. After sending this start sequence, the DLS-C(H)/FLS-C(H) is ready to use.
Distance Laser Sensor
M
EFERENCE
ANUAL
+
' sign as parameter separator. The '
Set command
sNuof+xxxxxxxx<trm>
gNuof?<trm>
gN@Ezzz<trm>
N
Device ID
xxxxxxxx
Offset in 1/10 mm; + positive / - negative
zzz
Error code
<trm>
<cr><lf>
with
N
.
+
' sign can be replaced by the minus '
sNuof<trm>
gNuof+xxxxxxxx<trm>
gN@Ezzz<trm>
gN?
. On this sequence, the
.
-
' sign if applicable by the
Get command
N
stands for the
Page 29/53