User Single Sensor Tracking With Timer(Snuh); User Tracking With Buffering - Start (Snuf); Read Out - User Tracking With Buffering (Snuq) - Dimetix DLS-C 15 Technical Reference Manual

Distance laser sensor dls-c series fls-c series
Hide thumbs Also See for DLS-C 15:
Table of Contents

Advertisement

T
R
ECHNICAL

9.4.3 User single sensor tracking with timer(sNuh)

This command does the same as the
This command takes the user distance offset and user gain into account
Never use this command if more than one device is connected to the RS-422 line
Command
Return successful
Return error
Parameters
9.4.4 User tracking with buffering – Start (sNuf)
Triggers continuous measurement of the distance with internal buffering in the device (buffer for one measurement). The measured
distance is corrected with the user offset and user gain as set with the command 9.5.2 Set/Get user distance offset (sNuof) and 9.5.3
Set/Get user distance gain (sNuga) on page 45. Define the rate of measurements with the sampling time. If the sampling time is set to zero,
the measurements are executed as fast as possible. The latest measurement can be read out from the device with the command
measurements are continued until the stop/clear command (sNc) is issued.
This command takes the user distance offset and user gain into account
Command
Return successful
Return error
Parameters
9.4.5 Read out – User tracking with buffering (sNuq)
After starting "User-configured tracking with buffering" with the command
C(H)/FLS-C(H).
This command takes the user distance offset and user gain into account
Command
Return successful
Return error
Parameters
Distance Laser Sensor
M
EFERENCE
ANUAL
sNuf
command, but the unit sends the results directly to the output.
Command
sNuh+xxx<trm>
gNuh+yyyyyyyy<trm>
gN@Ezzz<trm>
N
Device ID
xxx
Sampling time in 10ms (if 0 -> use max. possible sample rate)
yyyyyyyy
Distance in 0.1mm
zzz
Error code
Set command
sNuf+xxxxxxxx<trm>
GNuf?<trm>
gN@Ezzz<trm>
N
device ID
xxxxxxxx
Sampling time in 10ms (if 0 -> use max. possible sample rate)
zzz
Error code
Command
sNuq<trm>
gNuq+xxxxxxxx+c<trm>
gN@Ezzz+c<trm>
N
device ID
xxxxxxxx
Distance in 0.1mm
c
0 = no new measurement since last sNuq command
1 = one new measurement since last sNuq command, not overwritten
2 = more than one measurement since last sNuq command, overwritten
zzz
Error code
Get command
sNuf<trm>
gNuf+xxxxxxxx<trm>
gN@Ezzz<trm>
sNuf
, the latest measurement can be read out from the DLS-
sNuq
. The
Page 44/53