3.5 Special user commands

The standard command set is extended by a special user command set, which makes it possible to change the output format and apply a
offset and gain.
User command configuration do not influence Analog, Digital and SSI outputs.

3.5.1 Offset / Gain

The user can set an individual user gain and offset to create user defined output values. The output value is calculated as follows.
Value
=(Distance+Offset
User
With the offset and gain the result of the user commands (See 9.4 Special user operation commands on page 43) are changed only.
Analog, Digital and SSI output values are not affected.

3.5.2 Output format

The DLS-C(H)/FLS-C(H) is able to format the output value on the serial interface (RS-232/RS-422) in order to fit it to an ASCII display. By the
command
sNuo
the length of the output value can be defined as well as the position of the decimal point. This command in combination
with a gain and offset allows the direct connection of an external display as described under 2.3 External display on page 6.
The command is described under 9.5.4 User output protocol (sNuo) on page 46
Distance Laser Sensor
M
EFERENCE
ANUAL
GainNum
User
)⋅
User
GainDen
User
See 9.5.2 Set/Get user distance offset (sNuof) and
9.5.3 Set/Get user distance gain (sNuga) on page 45
Page 15/53