Zone Mode - Lutron Electronics QSGRK-6D Quick Installation And Operation Manual

Grafik eye qs with dali
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Daylight Sensor Setup

Zone Mode

This step allows you to assign sensors to each zone, with one daylight sensor per
zone connected to the GRAFIK Eye
more than one zone.
Select Sensors
Daylight Sensor
1. If not already done, complete the steps on page 17, and
Setup
select "Zone Mode".
2. Use the Master buttons to highlight "Setup" and press the
Calibrate
OK button to accept. Available sensors will be displayed.
3. You can assign one sensor per zone, and a sensor can be
assigned to more than one zone. Use the Master buttons to
scroll through the sensors until the one you wish to assign or
Saved
Searching
unassign is highlighted, and press the OK button to select it.
4. Use the zone raise and lower buttons for each zone to assign
or unassign the sensor to that zone. The zone raise button
assigns the displayed sensor, and the zone lower button
Sensor
x/y
unassigns it. Repeat for all desired sensors and press OK. A
screen will verify your settings have been saved.
SN: xxxx-xxxx:
5. Calibrate sensors: Press the Timeclock (back) button to return
Source: RF
to the Daylight Sensor screen. Use the Master buttons to
select the desired group and press the OK button to accept.
6. Use the Master buttons to select the desired zone and press
Sensor
x/y
the OK button to accept.
7. Put any wireless Radio Powr Savr
Select
associated with the desired zones into Calibrate Mode: Press
Zones
and hold the "Cal" button for 6 seconds until the sensor
flashes.
8. Use the Master buttons to select the desired light level for the
zone, and press the OK button to accept. Repeat for all zone
levels you wish to calibrate. Press the OK button to accept.
9. Exit programming mode (see page 9).
Note: If wireless sensors are not found, verify that they are
associated correctly (see page 16).
Daylight Sensor
Setup
3 seconds
Calibrate
®
1
9
QS control unit. Sensors can be assigned to
®
TM
Sensor Name
Adjust Light
More light
Zone 1
Less light
For additional information, see the complete installation and operation guide at www.lutron.com/qs
2
10
3
11
4
12
5
13
6
14
7
daylight sensors
Saved
Saved
GRAFIK Eye
QS with DALI Quick Installation and Operation Guide 18
®
15
8
16
9-16
1-8
OK
1
9
2
10
3
11
4
1
9
2
10
3
11
Master
buttons
OK
button
Timeclock
(back) button
12
5
13
6
14
7
15
8
16
4
12
5
13
6
14
Zone raise
Zone lower
Cal
button

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents