Fuel Pressure; Power Consumption Of The Hydraulic Propeller Governor; Power Consumption Of The Vacuum Pump; Power Consumption Of The External Alternator - Rotax 912 Series Operator's Manual

Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

Fuel pressure

Propeller
governor
Vacuum pump
External alternator
Bank angle
2.
applicable only for fuel pump from S/N 11.0036
Page 2-4
November 01/2016
Non-compliance can result in serious injuries or death!
Fuel pressure in excess of stated limit can lead to an override of the
float valve with subsequent engine stop.
The aircraft engine manufacturer strongly recommends the in-
stallation of an additional pump, unless this has not been cov-
ered by legal obligations so far.
Max.
0.4 bar (5.8 psi)
(0.5 bar (7.26 psi))
Min.
0.15 bar (2.2 psi)

Power consumption of the hydraulic propeller governor:

Max.
600 W

Power consumption of the vacuum pump:

Max.
300 W

Power consumption of the external alternator:

Max.
1200 W
Deviation from bank angle:
Max.
40°
NOTE
Up to this value the dry sump lubrication system warrants lubri-
cation in every flight situation.
BRP-Rotax
m WARNING
Fuel pressure
2