(4) "General Settings"
Set various items before the inspection. (Refer to Fig. 3.)
Note: The settings are not saved.
(4-2)
(4-1)
(4-1) "RS test port"
Set the COM port to be used for the RS test. (Default: COM1)
(4-2) "Print pattern"
Set the print pattern file to be used for the inspection.
In accordance with the table below, specify a file for each print pattern of the
"Print pattern" section in the "General settings" window.
Items to be examined
"Adjustment print test (continuous)"
"Adjustment print test (62mm 2Labels)"
"Adjustment print test (62mm 1Label)"
(4-3) Click the "OK" button after completing all settings.
Note: It is impossible to change other items than the above.
(4-3)
Fig. 3 Setting screen
4
File name (PRN file)
P102_ latest date.prn
P62100_Non_ latest date.prn
P62100_ latest date.prn