(10) 7 bit format first track data setting command (Model: TCP300)
This command sets the write data to the first track with a 7-bit format. Excluding 02h (STX)
and 03h (ETX), the write data string must be data from 01h to 7Eh in 0 to 69 bytes.
The starting and ending symbols, LRC and parity bit on the magnetic stripe are all automatically
applied. A reject response is issued when an error is detected in the write data.
This command cannot be used with on models with one magnetic stripe (TCP300).
Command Transfer Formats
STX
38h
Response Transfer Formats
STX
38h
(11) 7 bit format second track data setting command (Model: TCP300/310)
This command sets the write data to the second track with a 7-bit format.
Excluding 02h (STX) and 03h (ETX), the write data string must be data from 01h to 7Eh in 0 to
69 bytes.
The starting and ending symbols, LRC and parity bit on the magnetic stripe are all automatically
applied. A reject response is issued when an error is detected in the write data.
Note that this command can be used with on models with one magnetic stripe (TCP300).
Command Transfer Formats
STX
39h
Response Transfer Formats
STX
39h
Write data string
ETX
Status
ETX
Write data string
ETX
Status
ETX
BCC
BCC
BCC
BCC