Electrolux IC4 4819 FFS Service Manual page 217

Feeder ironer folder & stacker
Table of Contents

Advertisement

Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair
Replacement of the pressostat gas B1:
Setting: (next)
7. Turn to the right or left the setting screw of the pressostat so that the indicator is lit (Fig. 2).
8. Adjust the pressostat (Fig. 1) to the value of switching, ie the value at which the indicator
switches from ON to OFF and vice versa.
9. Vary the exhaust gas outlet in order to check the operation of the pressostat.
Example: for a IC4 4832, the pressostat is set to 5 mmH2O.
- Depression > 5 mmH2O :
- Depression = or < 5 mmH2O :
10. Once the adjustment is complete, block the setting screw of the pressostat with varnish
(Fig.1).
11. Stop the machine, disconnect the manometer and the Ohm-meter or the indicator +
power supply.
12. Reconnect the depression hose pipe and electric wiring of the pressostat.
13. Close the side frame of the machine.
Setting values of the pressostat :
IC4 48xx FFS
04102011/GB
50.2011
Gas heating
(electricity, steam, water, gas, compressed air...).
1.90 m
15 mmH2O
(147 Pa)
Pressostat closed = Indicator on
Pressostat open = Indicator off
2.50 m
9 mmH2O
(88 Pa)
25
3.20 m
5 mmH2O
(49 Pa)
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs