Operation - Electrolux IC4 4819 FFS Service Manual

Feeder ironer folder & stacker
Table of Contents

Advertisement

Service
Manual

Operation

Controlled by the ELECTROLUX ITS, the KM6, KM7 and KM8 contactors supply the heating
elements.
The B126, B127 and B128 temperature sensor (PT100) contribute to the regulation of the
temperature and the overheating detection of ironing cylinder according to the following
condition:
Overheating condition:
Overheating on side
Overheating on center
The F2 thermal fuse (T°C > 240°C) and the B3 safety thermostat (T°C > 210°C) are used like
thermal breaker to protect the machine against overheating > 210°C.
Power supply
3 phases
Q0
400
24
ARU
KM1
* ARU = Security chain, emergency push button
04102011/GB
06.2009
Electric heating
= 1
= 0
= 1
= 0
400
KM6
Heating ele. group 1
400
KM7
Heating ele. group 2
400
KM8
Heating ele. group 3
230
Q1
T1
T2
X118
X129
X112
KM2
KM3
when B126 >230°c or B128 > 230°c
when B126 & B128 < 200°c
when B127 > 240°c
when B127 < 240°c
Q3
F2
B3
X108
X109
X126
X127
X128
B126
B127
B128
24
B2
X111
X117
A1_BASE
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs

Table of Contents