The different functions of the «MACHINE TIMERS SETTING»:
• Cross 1-2 distance:
Adjustment of the difference of activation between the 1
Factory value
1060
• Cross 2-3 distance:
Adjustment of the difference of activation between the 2
Factory value
1910
• Cross 1 timer:
Adjustment of the activation time of the 1
Factory value
500
• Cross 2 timer:
Adjustment of the activation time of the 2
Factory value
500
• Cross 3 timer:
Adjustment of the activation time of the 3
Factory value
500
• Stack. center timer:
Adjustment of the centering of linen on the fl aps of the stacker.
Factory value
1860
• Stack. ejection timer:
Adjustment of the operation time of the pile ejection motor.
Factory value
7600
• Eject. roll up timer:
Adjustment of the height of stop of the ejection roller towards the transfer table.
Decrease the value if the roller comes in contact with the anti-static bar.
Factory value
70
04102011/GB
17.2012
ELECTROLUX ITS Screens
Minimum value
700
Minimum value
1600
cross fold.
st
Minimum value
100
cross fold.
nd
Minimum value
100
cross fold.
rd
Minimum value
100
Minimum value
1000
Minimum value
5000
Minimum value
35
and the 2
cross folds.
st
nd
Maximum value
1300
and the 3
nd
rd
Maximum value
2200
Maximum value
600
Maximum value
600
Maximum value
600
Maximum value
2500
Maximum value
8500
Maximum value
80
22
Incrementing
10
cross folds.
Incrementing
10
Incrementing
50
Incrementing
50
Incrementing
50
Incrementing
20
Incrementing
20
Incrementing
5
35